Eaton MTL4500 backplane-mounted IS isolators
Backplane-mounted intrinsic safety isolators for DCS, ESD and F&G – highest channel density, 3-port isolation, low power, many SIL-assessed models.
- Backplane mounting for direct DCS/ESD/F&G integration
- Highest module/channel packing density, single and multi-channel
- 3-port isolation, low dissipation, planar transformer technology
- Quick install-and-release, broken-line monitoring
- Many models assessed for functional safety (SIL)
- Replaces preceding MTL isolator ranges
Overview
The MTL4500 range of backplane-mounted intrinsic safety isolators protects electrical signals entering potentially flammable hazardous areas, helping keep people and plant safe.
Built around planar transformer technology and highly automated manufacture, MTL4500 is designed for system vendors and project applications such as DCS, ESD and F&G: fast module installation, easy integration, low-power circuits and more I/O channels per module.
Common modules
| Model | Function |
|---|---|
| MTL4511 | Switch/proximity input, 1 channel, relay output |
| MTL4516C | Switch/proximity input, 2 channels, line-fault detection |
| MTL4521 | Solenoid / alarm driver (DO) |
| MTL4531 | Temperature converter (RTD, TC) to 4–20 mA |
| MTL4541 | Repeater power supply 4–20 mA, HART, 1 channel |
| MTL4544 | Repeater power supply 4–20 mA, HART, 2 channels |
| MTL4546 | Isolating driver 4–20 mA for control valves, HART |
Applications
- DCS, ESD and F&G marshalling cabinets
- Refineries, offshore platforms and power plants
Viet Thang Loi Technology (VTL) is Eaton's representative in Vietnam. Contact VTL for model selection and a quotation.
| Hazardous area | Zone 0, Group IIC/IIIC outputs; Zone 2 / Class I Div 2 mounting |
|---|---|
| Temperature class | T4 |
| Ambient | −20 … +60 °C |
| Mounting | MTL4500 or DCS-specific backplanes |
| Approvals | ATEX, IECEx, FM/CSA |
Related products

Eaton MTL 949x-PS intrinsically safe power supplies
Isolated IS power supplies: 24 V DC in, Ex ia 4.8 – 17.7 V out for devices in Zone 0/1, gas groups IIB/IIC; mount in safe area or Zone 2.
View details →
Eaton MTL5500 DIN-rail IS isolators
MTL5500 DIN-rail intrinsic safety isolators: slim single and multi-channel modules, 3-port isolation and removable connectors – from single loops to full cabinets.
View details →
Eaton MTL7700 DIN-rail zener barriers
MTL7700 DIN-rail zener barriers divert excess energy safely to earth using zener diodes, resistors and fuses – compact, economical, removable terminals, IS earth via the rail.
View details →
Eaton MTL intrinsically safe fieldbus barriers
Fieldbus barriers providing intrinsically safe spurs from a high-energy trunk for FOUNDATION™ fieldbus H1 devices – mount in Zone 1/21, spurs into Zone 0.