Cảm biến nhiệt độ Baumer.
Phân phối đồng hồ đo nhiệt độ các loại của của Baumer trong các lĩnh vực công nghiệp như: Dầu khí, hóa dầu, hóa chất,...
Housing: DIN form B
Immersion: depth to 3000 mm
Output: 4 … 20 mA or HART output
Type: Pt100 class A/B, Pt1000-configurable
Bạn quan tâm đển sản phẩm này ?
Technical data
Performance characteristics
- Process temperature
-
- -50 … 400 °C
- -50 … 600 °C , optional
- Max. flow velocity
-
- 40 m/s , gases
- 5 m/s , liquids
- Pt100 accuracy class (EN 60751)
-
- B (± 0.3 °C at 0 °C)
- ± (0.3 + 0.005 × t)°C
- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- 1/6 B (± 0.05 °C at 0 °C)
- ± 1/6 × (0.3 + 0.005 × t)°C
- Pt1000 accuracy class (EN 60751)
-
- B (± 0.3 °C at 0 °C)
- ± (0.3 + 0.005 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- Response time, T50
-
- ≤ 1.5 s , Ø4 mm
- ≤ 6.1 s , Ø6 mm
- ≤ 7.6 s , Ø8 mm
- ≤ 11.1 s , Ø10 mm
Process connection
- Sensor length
-
- 20 … 3000 mm
- Sensor tube material
-
- AISI 316L (1.4404)
- Surface roughness wetted parts
-
- Ra ≤ 0.8 µm
Ambient conditions
- Degree of protection (EN 60529)
-
- IP 65
- Humidity
-
- ≤ 100 % RH , condensing
- Vibration (sinusoidal) (EN 60068-2-6)
-
- 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
- Without transmitter
-
- 1 x Pt100, 2-wire
- 1 x Pt100, 4-wire
- 2 x Pt100, 2-wire
- 1 x Pt1000, 2-wire
- With transmitter
-
- 4 … 20 mA , 2-wire
- 4 … 20 mA , + HART®
Compliance and approvals
- Railway applications
-
- EN 50155
- Explosion protection
-
- ATEX II 1G Ex ia IIC T4/T5
- ATEX II 3G Ex nA IIC T5
- Ex ia Simple apparatus, gas and dust
Data sheet
-
Data sheet – TCR6
Installation and operating instructions
-
Operating instructions – TCR6
Certificates / approvals
-
Declaration of Conformity – CE
-
Declaration of Conformity – CE - ATEX
-
Declaration of Conformity – CE - ATEX simple apparatus
-
Declaration of Conformity – EN50155
-
Type Examination Certificate / Type approval – ATEX II 1 G
-
Type Examination Certificate / Type approval – MTTF
Technical Reports / White Paper
-
Baumer Guideline for Analog Sensor Interfaces
-
Baumer Explosion Protection Guideline
Software
-
Software – PC Software FlexProgram
3D CAD
-
CAD-Drawing – TCR6