MTL7700 range

The MTL7700 range follows closely in the footsteps of the MTL700 but as a DIN rail mounting barrier providing quick and easy installation without the need for special hardware.
MTL7700 range

The MTL7700 range follows closely in the footsteps of the MTL700 but as a DIN rail mounting barrier providing quick and easy installation without the need for special hardware. Removable terminals are used for ease of installation, maintenance and for providing a loop disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures. MTL7700 barriers clamp simply and securely onto standard T-section DIN rail, simultaneously making a reliable IS earth connection. For applications where field power is required for switch inputs or 2-wire transmitters, the MTL7700 range provides a bussed power feed facility. When used in conjunction with the MTL7798 power feed module the user has a fully protected, electronically fused supply to many barriers with no additional wiring required.

  • Removable terminals - for easy cabling - UNIQUE
  • Bussed power - reduces cabling - UNIQUE
  • Barrier protection module
  • Proximity detector inputs - UNIQUE
  • Dual channel modules
  • Relay and solid state switch modules - UNIQUE

Về Eaton MTL Instruments

Eaton MTL Instruments, thành viên Tập đoàn Eaton (Hoa Kỳ), dẫn đầu toàn cầu về giải pháp chống sét tín hiệu, dữ liệu và nguồn điện với hơn 50 năm kinh nghiệm trong môi trường khắc nghiệt và khu vực nguy hiểm.

Công ty TNHH Kỹ thuật Việt Thắng Lợi là đại lý ủy quyền chính thức của Eaton MTL Instruments (MTL) và Eaton Crouse-Hinds (CEAG) tại Việt Nam. Vui lòng liên hệ với chúng tôi để được tư vấn và cung cấp thông tin chi tiết.

Bạn quan tâm đển sản phẩm này ?

SPECIFICATIONS

Model No. Safety description
V Ω mA
7706+ 28 300 93
7707+ 28 300 93
7707P+ 28 diode
7707P+ 28 164 171
7710+/- 10 50 200
7710P+ 10 33 300
7715+ 15 100 150
7715P+ 15 50 291
7722+/- 22 150 147
7728+ 28 300 93
7728- 28 300 93
7728ac 28 300 93
7728P+ 28 234 119
7729P+ 28 164 170
7772ac 22 300 73
774X 10 19
7751ac 1 10 100
7755ac 3 10 300
7756ac 3 10 300
7758+/- 7.5 10 750
7761ac 9 90 100
7761Pac 9 350 26
7764+/-/ac 12 1k 12
7766ac 12 150 80
7766Pac 12 75 157
7767+ 15 100 150
7768+ 22 150 147
7779+ 28 300 93
7796+ 26 300 87
7796- 20 390 51
7760ac 10 50 200
7765ac 15 100 150
7778ac 28 600 47
7789+ 28 300 93
7789+ 28 diode
7787+/- 28 300 93
7787+/- 28 diode
7787P+ 28 234 119
7787P+ 28 diode
7788+ 28 300 93
7788+ 10 50 200
7788R+ 28 300 93
7788R+ 10 50 200
Product Code Description Downloads
INA7700 MTL7700 range Instructions for Safe Use Manual
INM7700 MTL7700 range Instruction Manual Manual
MTL7700 MTL7700 is intrinsically safe MTL7700 range Specifications and Data Datasheet
MTL7700 MTL7700 range Active Barrier descriptions Datasheet
MTL7700 MTL7700 range Applications Datasheet
MTL7700 MTL7700 is intrinsically safe French version - MTL7700 range Specifications and Data Datasheet
MTL7700 ACC MTL7700 range Accessories Datasheet
intrinsically safe logo Symbol denotes that the equipment is suitable for use in hazardous area applications.
fsm logo Symbol denotes that the product has been assessed for functional safety applications

Sản phẩm tương đương